Zhongshan Hongling Electrical Appliance Co., Ltd.
holinpump.en.made-in-china.com
NO. 21, Longtan 3 road, No. 3 Industrial area, Tanzhou Town, Zhongshan City, Guangdong, China
Contact person: Miss Joyce Chen
Tel. 0086 760 22620552, Fax . 0086 760 22622349 Mobile phone, 0086 186 0756 7566
DC Pump
HL-1000DC
Specification:
Features:
Series product details:
SAFETY INSTRUCTIONS
Holinpump pumps are carefully inspected and tested to insure both safety and operating performance; However, failure to follow the instructions and warnings may result in pump damage and/or serious injury.
Warning
1, Risk of electric shock is certain that it is connected only to properly grounding-type receptacle.
2, Do not connect to any voltage other than that shown on the pump.
3, Do not pump flammable liquids
4, To reduce the risk of electrical shock, use only on portable self-contained fountains no larger than 5 feet in any dimension.
5, Do not use with water above 35C (95F).
6, Operate pump completely submerged for proper cooling.
7, Not for swimming pool.
Clearing
1, To clean the pump, remove the back cover and the impeller.
2, Use a small brush or stream of water to remove any debris
3, IF THE PUMP FAILS TO OPERATE, CHECK THE FOLLOWING:
4, Check the circuit breaker and try another outlet to ensure the pump is getting electrical power.
5, Check the pump discharge and tubing for kinks and obstructions. Algae build up can be flushed out with a garden hose.
6, Check the inlet to ensure it is not clogged with debris.
7, Remove the pump inlet to access the impeller area. Turn the rotor to ensure it is not broken or jammed.
8, Monthly maintenance will add to your pump's life
9, We guarantee our products for a period of 12 months
holinpump.en.made-in-china.com
NO. 21, Longtan 3 road, No. 3 Industrial area, Tanzhou Town, Zhongshan City, Guangdong, China
Contact person: Miss Joyce Chen
Tel. 0086 760 22620552, Fax . 0086 760 22622349 Mobile phone, 0086 186 0756 7566
DC Pump
HL-1000DC
Specification:
No. | Items | Specs | ||
1 | Size and weight | 83mm*57mm*76mm | ||
2 | Dimension of outlet | 25mm | ||
3 | Driving method | Brushless, Permanent Magnetic | ||
4 | Pump material | ABS | ||
5 | Condition of use | Submersible | ||
6 | Fluids | Fresh and salt Water | ||
7 | Max working temp | 60 Celsius | ||
8 | Power consumption | 18w | ||
9 | Rated voltage | 12vdc/24vdc | ||
10 | Max flow rate | 1000L/h (264G/h) | ||
11 | Max static head | 2M (6.6ft) | ||
12 | Noise | <35dB | ||
13 | Water proof class | IP68(submersible installed) | ||
14 | Life span | More than 30000hrs | ||
15 | Power supply | Solar panel; DC electric source; Adapter; battery | ||
16 | Protection Function | Blocking Protection (Optional) |
Features:
1, DC12V/24V, low-voltage, safe, NO.1 aquarium submersible pump in china. | |||||||||
2, 100% copper motor, brushless, non-pollution, small size with high efficient ,long life span. | |||||||||
3, maintenance-free, low consumption, good anti-jamming ability, low noise and stable | |||||||||
4, super energy saving 50%. | |||||||||
5, Small size, high efficiency, maintenance-free, low consumption, strong anti-jamming ability, stable performance. | |||||||||
6, Brushless with no pollution, long life span. | |||||||||
7, Adopt silicone foot to absorb vibration &reduce noise,easy for installation. | |||||||||
8, Stator and control circuits are completely sealed by epoxy resin completely separated with rotor, waterproof, avoided water-leakage problem which long exists in normal DC motor pump products. | |||||||||
9, Protection functions can be customized such as lock protection, dry-run protection and so on. | |||||||||
10, Reduced the mortality to 0.05% after long-time study by R&D dep. | |||||||||
11, Suitable for submersible installation or land use (should be located below fluid level). | |||||||||
12, Offer ODM serve for pump and other controller system. |
Series product details:
Model | Product photo | Watt | Voltage | Working voltage | Max flow rate | Max height | Product size | Outer fitting size | |
HL-180DC-1 | Bitmap | 3W | 12V DC | 11-17V DC | 180 | 1.2m | 37x37x29mm | 8mm | |
HL-180DC-2 | Bitmap | 3W | 12V DC | 11-17V DC | 180 | 2.1m | 37x37x29mm | 8mm,13mm | |
HL-280DC | Bitmap | 4W | 12V DC | 11-17V DC | 280 | 1.2m | 48x43x31mm | 8mm,13mm | |
HL-600DC | Bitmap | 7W | 12V DC | 11-17V DC | 600 | 1.6m | 65x45x50mm | 15mm,20mm | |
HL-800DC | Bitmap | 8W | 12V DC | 11-17V DC | 800 | 2.0m | 75x52x72mm | 15mm,20mm | |
HL-1000UDC | Bitmap | 18W | 12V DC | 11-17V DC | 1000 | 2.0m | 83x57x76mm | 25mm | |
HL-1500DC | Bitmap | 17W | 12V DC | 11-17V DC | 1500 | 2.5m | 100x68x93mm | 25mm | |
HL-2000DC | Bitmap | 22W | 12V DC | 11-17V DC | 2000 | 3.0m | 135x88x165mm | 25mm |
Holinpump pumps are carefully inspected and tested to insure both safety and operating performance; However, failure to follow the instructions and warnings may result in pump damage and/or serious injury.
Warning
1, Risk of electric shock is certain that it is connected only to properly grounding-type receptacle.
2, Do not connect to any voltage other than that shown on the pump.
3, Do not pump flammable liquids
4, To reduce the risk of electrical shock, use only on portable self-contained fountains no larger than 5 feet in any dimension.
5, Do not use with water above 35C (95F).
6, Operate pump completely submerged for proper cooling.
7, Not for swimming pool.
Clearing
1, To clean the pump, remove the back cover and the impeller.
2, Use a small brush or stream of water to remove any debris
3, IF THE PUMP FAILS TO OPERATE, CHECK THE FOLLOWING:
4, Check the circuit breaker and try another outlet to ensure the pump is getting electrical power.
5, Check the pump discharge and tubing for kinks and obstructions. Algae build up can be flushed out with a garden hose.
6, Check the inlet to ensure it is not clogged with debris.
7, Remove the pump inlet to access the impeller area. Turn the rotor to ensure it is not broken or jammed.
8, Monthly maintenance will add to your pump's life
9, We guarantee our products for a period of 12 months